Office:
Advantage Tactile Systems
241 Main Street, Suite 100
Buffalo, NY 14203
T:
1-800-679-4022
F:
1-800-679-4023
sales@advantagetactile.com
Advantage Tactile
Detectable warning pavers installations, the most superior durability of any product on the market! more..
|
Ultimate Solution ™
In Stainless Steel Detectable Warning
Cast In Place Detectable Warning Tile Installation |
Cast In Place Detectable Warning Tiles installation. Advantage Tactile System has the strongest detectable warning tiles systems.
|
Cast In Place Detectable Warning Tile Installation
Click Here for Surface Applied Detectable Warning Tile Installation
Installation Manual
Advantage Cast In Place
Inline Dome Cast In Place Detectable Warning Tile Installation
Download Cast In Place Detectable Warning Tile Installation Instructions as PDF
Download Cast In Place Detectable Warning Tile Installation Instructions as Word Document
- During Cast In Place Detectable Warning Tile installation procedures, ensure adequate safety guidelines are in place and that they are in accordance with the applicable industry and government standards.
- Prior to placement of the Cast In Place Detectable Warning Tile installation system, review manufacturer and contract drawings with the Contractor prior to the construction and refer any and all discrepancies to the Engineer.
- The Cast In Place Detectable Warning Tile installation specifications of the structural embedment flange system and related materials shall be in strict accordance with the contract documents and the guidelines set by their respective manufacturers. Not recommended for asphalt applications.
- The physical characteristics of the concrete shall be consistent with the contract specifications while maintaining a slump range of 4 - 7 to permit solid placement of the Cast In Place Detectable Warning Tile installation system. An overly wet mix will cause the tile to float. Under these conditions, suitable weights such as 2 concrete blocks or sandbags (25 lb) shall be placed on each tile.
- The Cast In Place Detectable Warning Tile installation concrete pouring and finishing operations require typical mason’s tools, however, a 4’ long level with electronic slope readout, 25 lb. weights, and a large non-marring rubber mallet are specific to the installation of the Cast In Place Detectable Warning Tiles system. A vibrating mechanism such as that manufactured by Vibco can be employed, if desired. The vibrating unit should be fixed to a soft base such as wood, at least 1 foot square.
- The factory-installed plastic sheeting must remain in place during the entire installation process to prevent the splashing of concrete onto the finished surface of the tile.
- When preparing to set the tile for the Cast In Place Detectable Warning Tile installation, it is important that no concrete be removed in the area to accept the tile. It is imperative that the installation technique eliminates any air voids under the tile. Holes in the tile perimeter allow air to escape during the installation process. Concrete will flow through the large holes in each embedment flange on the underside of the tile. This will lock the tile solidly into the cured concrete.
- The concrete shall be poured and finished true and smooth to the required dimensions and slope prior to the tile placement. Immediately after finishing concrete, the electronic level should be used to check that the required slope is achieved. The Cast In Place Detectable Warning Tile installation tile shall be placed true and square to the curb edge in accordance with the contract drawings. The Cast In Place Detectable Warning Tiles shall be tamped (or vibrated) into the fresh concrete to ensure that the field level of the tile is flush to the adjacent concrete surface. The embedment process should not be accomplished by stepping on the tile as this may cause uneven setting, which can result in air voids under the tile surface. The contract drawings indicate that the tile field level (base of truncated dome) is flush to adjacent surfaces to permit proper water drainage and eliminate tripping hazards between adjacent finishes.
- In cold weather climates it is recommended that the Cast In Place Detectable Warning Tiles be set deeper such that the top of domes are level to the adjacent concrete on the top and sides of ramp and that the base of domes to allow water drainage. This installation will reduce the possibility of damage due to snow clearing operations.
- Immediately after Cast In Place Detectable Warning Tile installation placement, the tile elevation is to be checked to adjacent concrete. The elevation and slope should be set consistent with contract drawings to permit water drainage to curb as the design dictates. Ensure that the field surface of the tile is flush with the surrounding concrete and back of curb so that no ponding is possible on the tile at the back side of curb.
- While concrete is workable, a 3/8" radius edging tool shall be used to create a finished edge of concrete, then a steel trowel shall be used to finish the concrete around the tile’s perimeter, flush to the field level of the tile.
- During and after the Cast In Place Detectable Warning Tile installation and the concrete curing stage, it is imperative that there is no walking, leaning or external forces placed on the tile that may rock the tile causing a void between the underside of tile and concrete.
- Following tile placement, review installation tolerances to contract drawings and adjust tile before the concrete sets. Two suitable weights of 25 lb each may be required to be placed on each tile as necessary to ensure solid contact of the underside of tile to concrete.
- Following the concrete curing stage, protective plastic wrap is to be removed from the tile surface by cutting the plastic with a sharp knife, tight to the concrete/tile interface. If concrete bled under the plastic, a soft brush will clean the residue without damage to the Cast In Place Detectable Warning Tile installation surface.
Click Here for Surface Applied Detectable Warning Tile Installation
|
|
|